How people and vehicles get through an automatic gate: keypads, remotes, intercoms, app entry and exit sensors, and the fire-department access each town expects.
Exit sensors
With a sensor ahead of the gate. DoorKing places an automatic exit loop 20 to 100 ft from the gate, so the gate is open or opening as the vehicle arrives.1
What it costs
These are national cost-guide figures, not local quotes.
This page covers four kinds of access control: keypads, remote transmitters, intercoms, and vehicle exit sensors. National add-on costs are in the table above, and the fire authority’s rules shape which of them a gate needs.
Not in Windsor. Windsor Severance Fire Rescue requires a Knox Key Switch on electric gates and will not accept access only via a private keypad.5 For manual gates, Windsor Severance Fire Rescue requires a Knox Padlock or Knox Box rather than a plain padlock.5
Fort Collins words it differently. Electric gates need a means of opening the gate by fire department personnel for emergency access, and emergency opening devices must be approved by the fire code official; manual gates cannot be locked with a padlock unless it is approved by the fire code official and compatible with the fire department’s key boxes.6 In Fort Collins, D103.5 item 9 also requires electric gate operators, where provided, to be listed to UL 325.6
Elsewhere the text differs again. Loveland Fire Rescue Authority, Windsor Severance Fire Rescue and the Town of Johnstown each carry an exception for private driveways serving one single-family residence, as approved by the fire code official.789 Greeley has not adopted Appendix D; its code adopts Appendices B and C, so a gate there falls under the general security-gate section, 503.6.10 The fire-access guide compares every town line by line.
Ahead of the gate on the way out. DoorKing places an automatic exit loop 20 to 100 ft from the gate, so the gate is open or opening as the vehicle arrives, and gives 18 by 48 in as the minimum loop size, at least 4 ft from the gate and from other loops.1
On LiftMaster’s LA400UL, yes. Its troubleshooting chart lists an active open control, an active vehicle loop detector and an active fire department input among the causes of a gate that opens but won’t close, and an active vehicle loop detector among the causes of one that closes but won’t open.11 Gate opener repair has the rest of that chart.
Access control sits on top of the opener: a new gate starts with automatic gate installation, operator ratings in the cold are in the cold-weather guide, and the driveway gate cost page has installed costs.
Common questions
HomeGuide (2023) puts a gate keypad at $100 to $800 nationally.2 That is a national figure, not a local quote.
HomeGuide (2023) puts remotes at $75 to $300 each.2 That is a national figure, not a local quote.
No. Windsor Severance Fire Rescue will not accept access only via a private keypad and requires a Knox Key Switch on electric gates.5
A means of opening the gate by fire department personnel for emergency access, with emergency opening devices approved by the fire code official.6 The adopted text does not name a device brand.
DoorKing gives 18 by 48 in as the minimum loop size, with loops at least 4 ft from the gate and from other loops.1
A buried probe that detects a vehicle leaving. Mighty Mule's FM138 has a 12 ft detection field on a 50-ft cable and is placed 3 to 50 ft from the gate.4